Icon View Incident Report

Serious Serious
Reported By: Jose Eduardo Helminsky
Reported On: 12/6/2001
For: Version 3.03 Build 1
# 973 UpgradeTable Not Converting BCD Fields Properly when Regional Settings Do Not Use Period for Decimal

I am starting to convert some tables to 3.03 version to do some tests before bought 3.04. But I for my surprise when I convert some tables and saw the results, all BCD fields became wrong. For example:

Field1 = 100,00 (version 2.12)
Field1 = 00.100 (version 3.03)

The regional settings are Portuguese (Brazil) on the machine.


Comments Comments
There was a problem with the display format being used for formatting BCD fields during the upgrade as they were converted to native TBCD type. This bug would also affect the display and edit formatting of BCD fields in the DBSYS utility, although that is a cosmetic issue.


Resolution Resolution
Fixed Problem on 12/8/2001 in version 3.04 build 1
Image