Reported By: Robert Perelegre Reported On: 5/27/2009 For: Version 2.02 Build 13
# 3001Upgrade Reverse-Engineering Not Working Properly in Unicode EDB Manager We have 2 databases: test1,test2
test1 has one table with one column.
test2 has the same table (that test with another column more).
Then, If I try to upgrade test1 to test2 with "Reverse-Engineer Database". I obtain a "Exception class EInvalidPointer with message 'Invalid pointer operation'."
CommentsThis is actually "pre-release" functionality that is for inclusion with 2.03, but is available now in the EDB Manager. Also, fixed a minor issue with compiling the EDB Manager with the ANSI version of the engine under Delphi 2009.
ResolutionFixed Problem on 5/28/2009 in version 2.02 build 14
Products AffectedElevateDB Additional Software and Utilities