Reported By: Peter Kaufman Reported On: 3/19/2016 For: Version 2.22 Build 2
# 4372Unicode Tables Reporting Trunction Errors When Edited Using Microsoft Access The ODBC driver works perfectly in Access. I don’t need to do any further testing there. But there are issues with truncation of fields that should be okay. Some ElevateDB varchar(50) fields are not accepting 50 chrs – more like 15.
CommentsThe issue was with an internal workaround in the ODBC driver's SQLBindParameter function that caused a side-effect that resulted in parameters being sized too small for Unicode string buffers.
ResolutionFixed Problem on 3/21/2016 in version 2.23 build 1
Products AffectedElevateDB DAC Client-Server ElevateDB DAC Client-Server with Source ElevateDB DAC Standard ElevateDB DAC Standard with Source ElevateDB DAC Trial