Icon View Incident Report

Serious Serious
Reported By: Elevate Software
Reported On: 3/22/1998
For: Version 0.03 Build 1
# 65 BCD Fields Are Incorrectly Being Shifted Over After the Decimal Point

BCD fields are getting shifted over one place after being entered, for example 0.009 gets converted into 0.9 after exiting the control.


Resolution Resolution
Fixed Problem on 3/23/1998 in version 0.04 build 1