Icon View Incident Report

Serious Serious
Reported By: Ben Sprei
Reported On: 2/25/2012
For: Version 2.07 Build 1
# 3548 Close Table Context Menu Option Not Updating Properly After Altering a Table in ElevateDB Manager

Right Click a table | Open
While the table is open Right click the same table | Alter Table
The table closes and you can alter the table
Exit from Alter Table
Right Click the same table (its closed now) and the context menu shows
"close table" instead of "open table".
When you select close table nothing happens because the table is not open.
Right click againg and the context menu shows open table.


Comments Comments
The problem was with the ElevateDB Manager improperly closing the table when the Alter Table operation/dialog was cancelled.


Resolution Resolution
Fixed Problem on 2/25/2012 in version 2.08 build 1


Products Affected Products Affected
ElevateDB Additional Software and Utilities

Image