Icon View Incident Report

Serious Serious
Reported By: Terry Swiers
Reported On: 7/13/2009
For: Version 2.02 Build 14
# 3028 Reverse-Engineering Dialog in EDB Manager Reports Database Error When Cancelling Upgrade

If you start a reverse engineer of a database, select "Upgrade" as the type, it won't let you cancel unless you select another database. If you change the type back to "Create", it will let you cancel.


Comments Comments
The condition for this to happen is a session with only one database defined in the configuration file used for that session.


Resolution Resolution
Fixed Problem on 7/13/2009 in version 2.02 build 15


Products Affected Products Affected
ElevateDB Additional Software and Utilities

Image