Posted by Tim Young on Wed, Sep 29 2010
ElevateDB 2.04 Build 3 is now available for download. This build introduces support for the new Embarcadero Delphi XE product line. It also contains bug fixes for several incident reports, which are detailed here.

2.04 B3 Configuration Fix
There is an issue with the streaming of locking information for any modules created using the CREATE MODULE statement with 2.04 Build 1 or 2. This issue is detailed here:

# 3313 Configuration Not Properly Saving Locking Information for Created Modules

If you have created any modules using the CREATE MODULE statement with 2.04 Build 1 or 2, including any migrator modules auto-created for you using the ElevateDB Manager's Create Database Migrators option, then you must run a utility to fix the configuration where the module information is stored. This utility is called edbfix204config.exe and is a command-line application located in the:

\utils\edbfix204config

subdirectory under the main installation directory for the ANSI utility, and in the:

\utils\edbfix204configunicode

subdirectory for the Unicode utility.

To run this utility, open a command prompt under Windows and type in the utility name followed by a space and the path of the configuration file that you wish to fix. For example, if you want to fix the configuration file in the c:\myapplication directory, you can do so by using the following command:

<InstallDir>\utils\edbfix204config c:\myapplication

The most important parameter to the utility is the configuration path, but there are also other parameters for configurations that use non-standard encryption passwords, signatures, extensions, etc. You can find out the order of these parameters by executing the utility without any parameters specified, which will result in the utility outputting a description of the various parameters to the command window.

If the configuration file is fixed successfully, then a copy of the original configuration file will be saved in the same configuration path with an extension of .old. If any errors are encountered during the execution of the utility, the error will be output to the command window and the utility will terminate with an exit code of 1.